Unlike traditional systems which use special pliers to clamp the copper compressor pipes, the AFR drills the compressor from underneath which removes 98% of all oil and Freon gas. Plugging the drilled hole after drainage ensures the old compressor stays drip free. A leak test before drilling guarantees no CFC leakage.
Features:
- Designed as a stand alone unit or for use in automated refrigerator recycling systems.
- Fast powerful drilling action for 6-10 second drill time
- Large drill chamber for less maintenance and down time
- Clear see-through visualizes when all oil has been drained
- Fitted with an emergency stop button for safety
- Can be used with all CFC gas removing pumps or to our own powerful 1 HP unit.
- High quality as it’s „Made in Austria“ by an ISO certified company (CE and TÜV approval)
De-pollution process:
- Remove the compressor over the drilling table
- Press the start button, the AFR will clamp the compressor, drilling, draining and separation of oil and CFC gas occurs fully automated.
- As soon as the cycle is complete the AFR will stop automatically, releasing the compressor and signal that the compressor can be plugged and removed.
- The coolant system is now empty, the drilled hole is closed and the compressor is ready to be recycled.
We strongly recommend the SEDA AFR complete-set!